NON-CONTACT CAN SENSOR SP7001, SP7002

NON-CONTACT CAN SENSOR SP7001, SP7002

Kategori: Probes Sensors

Key Features Acquire CAN FD/CAN data immediately, simply by pinching probes over wire insulation with one-hand Eliminate concerns by using non-contact sensing technology Use in a diverse array of development and evaluation applications that demand reliability

Basic specifications

Detection methodCapacitive-coupled signal detection
No bare-wire connections
Detectable cablesAVS/AVSS-compliant cables, External diameter: 1.2 mm (0.05 in) to 2.0 mm (0.08 in)
Number of channels1 CH (SP7150), 2 CH (SP7100)
Compatible communications speedsSP7001: CAN, CAN FD 125 kbit/s to 3 Mbit/s
SP7002: CAN 125 kbit/s to 1 Mbit/s
Total delay time130 ns (typical)
CAN terminal resistance60 Ω (typical), built-in
Signal output connectorD-sub 9-pin female
Operating temperature, humidityTemperature: -40 °C to 85 °C (-40 °F to 185 °F)
Humidity: -40 °C to 60 °C (-40 °F to 140 °F), 80% RH or less (with no condensation), 60 °C to 85 °C (140 °F to 185 °F), 60% RH or less (with no condensation)
Power supply(1) When using the SP7001-95 or SP7150
- USB bus power (5 V DC), Maximum rated power: 8 VA
- Z1013 AC Adapter: Rated supply voltage: 100 V to 240 V AC, Maximum rated power: 6 VA (including AC adapter), 1 VA (product only)

(2) When using the SP7001-90, SP7002-90, or SP7100
- Z1008 AC Adapter: Rated supply voltage: 100 V to 240 V AC, Maximum rated power: 8 VA (including AC adapter), 3 VA (product only)
- External power supply: Rated supply voltage: 10 V to 30 V DC, Maximum rated power: 3 VA
Dimensions and mass (*1)SP7001, SP7002: 44 W × 85 H × 20 D mm (1.73 in. W × 3.35 in. H × 0.79 in. D), 180 g (6.35 oz.), Cable length: 2.5 m (8.20 ft.)
SP7100: 55 W × 120 H × 25 D mm (2.17 in. W × 4.72 in. H × 0.98 in. D),130 g (4.59 oz.), Cable length: 0.3 m (0.98 ft.)
SP7150: 47 W × 100 H × 20 D mm (1.85 in. W × 3.94 in. H × 0.79 in. D),100 g (3.52 oz.), Cable length: 0.3 m (0.98 ft.)
SP9250:10.5 W × 24.5 H × 101 D mm (0.41 in. W × 0.96 in. H × 3.98 in. D),45 g (1.59 oz.), Cable length: 0.8 m (2.62 ft.)
SP9200: φ11.6 × 33.7 H mm (φ0.46 in. × 1.33 in.), 26 g (0.92 oz.), Cable length: 0.5 m (1.64 ft.)
Included accessories (SP7001, SP7002)Quick Start Manual ×1, Operating Precautions ×1
Included accessories (SP7100)Quick Start Manual ×1, Operating Precautions ×1, Spiral tube ×1, Power cable L9500 ×1, Alligator clip ×1, Ground connection cable ×1
Included accessories (SP7150)Quick Start Manual ×1, Operating Precautions ×1, Spiral tube (for fixing power cable) ×1, USB Cable L9510 ×1, Ground connection cable ×1, Alligator clip ×1
  • *1:Dimensions do not include cables. Mass includes cables.

Produk Terkait

DIFFERENTIAL PROBE P9000

DIFFERENTIAL PROBE P9000

• Probe kompak untuk lingkungan CAT III 1000V • Mode gelombang: Mengamati bentuk gelombang sesaat • Mode RMS: Amati bentuk gelombang nilai RMS • Area penggunaan utama 1. Sirkuit baterai tegangan tinggi pada EV, HEV, dan mobil lain 2. Sirkuit bertegangan tinggi pada peralatan terkait energi seperti sel fotovoltaik 3. Sirkuit saluran listrik komersial (480 Vrms, dll.) 4. Suara lonjakan tegangan tinggi dari inverter, motor, solenoida, dll.

Probes Sensors Hioki
Detail Produk
AC FLEXIBLE CURRENT SENSOR CT9667

AC FLEXIBLE CURRENT SENSOR CT9667

Key Features Thinner cables are easy to use in confined spaces and with complicated wiring (-01, -02) Shaped so that it’s easy to route through complex wiring Easily supports large current measurements up to 5000 A Wide 10 Hz to 20 kHz band with excellent frequency characteristics Choose from three conductor diameter sizes Combine with Hioki power meters or Memory HiCorders (with BNC input terminals)

Probes Sensors Hioki
Detail Produk
AC/DC CURRENT SENSOR CT6877

AC/DC CURRENT SENSOR CT6877

Key Features Combined accuracy with HIOKI power analyzer PW8001, PW6001 and PW3390 is specified. For details of combined accuracy, refer to the instruction manual. Measures high-current up to 2000 A for EV, HEV and other electric vehicles Improved noise resistance performance through a stronger shield lets you accurately measure current buried in noise High accuracy measurement realized through flat frequency characteristics and CMRR performance More enhanced environmental resistance performance than ever before lets you measure in -40 to 85°C situations Superior frequency characteristics of DC to 1 MHz (amplitude) Meet a wide range of applications from measuring battery charge/discharge to the secondary side of inverters in photovoltaic power generation and fuel cell evaluation, etc. Monitor waveforms when paired with oscilloscopes or Memory HiCorders and Sensor Unit

Probes Sensors Hioki
Detail Produk
AC/DC CURRENT SENSOR CT6873

AC/DC CURRENT SENSOR CT6873

Key Features Combined accuracy with HIOKI power analyzer PW8001, PW6001 and PW3390 is specified. For details of combined accuracy, refer to the instruction manual. Wide-bandwidth DC to 10 MHz excellent frequency characteristics. Applications in the fields of electric and hybrid electric vehicles. Wide operating temperature range(-40°C to 85°C) fit for automobile applications. Ideal for evaluation of solar power generation and fuel cells to measure battery charge and discharge and the secondary side of inverters. For observing waveforms to be used with the oscilloscopes or Memory HiCorders (use with Sensor Unit).

Probes Sensors Hioki
Detail Produk