The PW3335 Power Meter delivers a range configuration that lets you measure extremely low power levels with a margin to spare. Accuracy can be set from 10 μA and up for current, and 0 W and up for effective power. Perfect for measurements according to IEC62301 and other standards.

When an AC adapter or switching power supply operates with no load, the crest factor of the current waveform increases. The PW3335 can measure waveforms that exceed the range of watt meters that support crest factor 3.
In addition, although the power factor is low during no-load operation, the PW3335 is affected very little by power factor and can therefore achieve accurate measurements.

A no-load loss test is one indicator for evaluating energy conservation for transformers and motors.
The PW3335 are affected very little by power factor, at ±0.1% f.s. or less, allowing active power to be measured with a high level of accuracy at low power factors.

| Measurement lines | Single-phase/ two-wires |
|---|---|
| Measurement items | Voltage, current, active power, apparent power, reactive power, power factor, phase angle, frequency, maximum current ratio, current integration, active power integration, integration time, voltage waveform peak value, current waveform peak value, voltage crest factor, current crest factor, time average current, time average active power, voltage ripple rate, current ripple rate |
| Harmonic parameters | Synchronization frequency range : 10 Hz to 640 Hz Maximum analysis order : 50th Harmonic voltage RMS value, harmonic current RMS value, harmonic active power, total harmonic voltage distortion, total harmonic current distortion, fundamental wave voltage, fundamental wave current, fundamental wave active power, fundamental wave apparent power, fundamental wave reactive power, fundamental wave power factor (displacement power factor), fundamental wave voltage current phase difference, harmonic voltage content percentage, harmonic current content percentage, harmonic active power content percentage (The following parameters can be downloaded as data with only PC communications : Harmonic voltage phase angle, harmonic current phase angle, harmonic voltage current phase difference) |
| Measurement ranges | [Voltage] AC/DC 6 V to 1000 V, 8 ranges [Current] AC/DC 1 mA to 20 A, 14 ranges [Power] 6.0000 mW to 20.000 kW (Depends on combination of voltage and current range) Effect of power factor : ±0.1% f.s. or less (45 to 66 Hz, at power factor = 0) |
| Integration measurement (Integration time up to 10,000 hours) | Switchable between fixed-range integration and auto-range integration. [Current] No. of displayed digits: 6 digits (from 0.00000 mAh, polarity-independent integration and sum value) [Active power] No. of displayed digits: 6 digits (from 0.00000 mWh, polarity-independent integration and sum value) |
| Input resistance (50/60 Hz) | [Voltage input terminal] 2 MΩ [Current input terminal] 520 mΩ or less (at 1 mA to 100 mA range), 15 mΩ or less (at 200 mA to 20 A range) |
| Basic accuracy (Active power) | ±0.1% rdg. ±0.1% f.s. (DC) ±0.1% rdg. ±0.05% f.s. (45 Hz to 66 Hz, at input < 50% f.s.) ±0.15% rdg. (45 Hz to 66 Hz, at 50% f.s. ≤ input) |
| Display refresh rate | 5 times/s to 20 seconds (depend on average times settings) |
| Frequency characteristics | DC, 0.1 Hz to 100 kHz |
| D/A output (-02/-04 models only) | 7 channels (selectable from the following items): level output DC ±2 V f.s. or 5 V f.s., waveform output 1 V f.s., level output, instantaneous waveform output (voltage, current, active power), level output (apparent power, reactive power, power factor, or other), high-speed level output (voltage, current, active power) |
| Functions | [Rectification method] AC+DC, AC+DC Umn, AC, DC, FND, Auto-range, Average, VT or CT ratio settings, Synchronized control, MAX/MIN, and more |
| Logger connectivity | Sends measured values wirelessly to logger by using a Bluetooth® wireless technology serial conversion adapter. (Supported devices: Hioki LR8410 Link-compatible loggers), Ver. 1.1 and later, the PW3335-01 is not supported |
| Interfaces | LAN (all models), RS-232C (except -01 model, for communication/LR8410 link), GP-IB (-01, -04 models only) |
| Power supply | 100 V to 240 V AC, 50/60 Hz, 30 VA max. |
| Dimensions and mass | 210 mm (8.27 in)W × 100 mm (3.94 in)H × 245 mm (9.65 in)D, 3 kg (105.8oz) |
| Included accessories | Instruction manual ×1, power cord ×1, voltage and current input terminal safety cover ×2, safety cover installation screws (M3 × 6 mm) ×4 |
Key Features Acquire CAN FD/CAN data immediately, simply by pinching probes over wire insulation with one-hand Eliminate concerns by using non-contact sensing technology Use in a diverse array of development and evaluation applications that demand reliability
• Probe kompak untuk lingkungan CAT III 1000V • Mode gelombang: Mengamati bentuk gelombang sesaat • Mode RMS: Amati bentuk gelombang nilai RMS • Area penggunaan utama 1. Sirkuit baterai tegangan tinggi pada EV, HEV, dan mobil lain 2. Sirkuit bertegangan tinggi pada peralatan terkait energi seperti sel fotovoltaik 3. Sirkuit saluran listrik komersial (480 Vrms, dll.) 4. Suara lonjakan tegangan tinggi dari inverter, motor, solenoida, dll.
Key Features Thinner cables are easy to use in confined spaces and with complicated wiring (-01, -02) Shaped so that it’s easy to route through complex wiring Easily supports large current measurements up to 5000 A Wide 10 Hz to 20 kHz band with excellent frequency characteristics Choose from three conductor diameter sizes Combine with Hioki power meters or Memory HiCorders (with BNC input terminals)
Key Features Combined accuracy with HIOKI power analyzer PW8001, PW6001 and PW3390 is specified. For details of combined accuracy, refer to the instruction manual. Measures high-current up to 2000 A for EV, HEV and other electric vehicles Improved noise resistance performance through a stronger shield lets you accurately measure current buried in noise High accuracy measurement realized through flat frequency characteristics and CMRR performance More enhanced environmental resistance performance than ever before lets you measure in -40 to 85°C situations Superior frequency characteristics of DC to 1 MHz (amplitude) Meet a wide range of applications from measuring battery charge/discharge to the secondary side of inverters in photovoltaic power generation and fuel cell evaluation, etc. Monitor waveforms when paired with oscilloscopes or Memory HiCorders and Sensor Unit