Key Features Add measurement modules as needed to create the measurement system you need [LR8102] Add channels by synchronizing sampling across multiple loggers [LR8102] Transfer high-speed data in real time
Accuracy guaranteed: 1 year
| Product model | Data Logger LR8102 | Data Logger LR8101 |
|---|---|---|
| Modules that can be connected | See [Options] > [Connectable measurement modules] | |
| Maximum number of module connections | 10 (maximum of 4 units for M7103) | |
| Maximum number of synchronizable loggers | 10 (Requires optical connection cables) | N/A |
| Power supply | AC adapter: AC Adapter Z1016 (operates on 12 V DC ±10%) External power supply: 10 V DC to 30 V DC AC Power Module M1100: Always required when using the Power Measurement Module M7103. | |
| Operating temperature and humidity range | −10°C to 50°C (14°F to 122°F), 80% RH or less (non-condensing) | |
| Number of LAN ports | 2 | 1 |
| Communication interface | [LAN1 functionality] Collecting data and setting recording conditions using Logger Utility Setting the initial IP address using Logger Utility Setting and controlling recording using communication commands Manually acquiring data using an FTP Server Automatically sending data via FTP (FTP client) HTTP server function XCP on Ethernet (TCP) NTP client function [LAN2 functionality] XCP on Ethernet (UDP) Measurement data can be output by UDP | [LAN1 functionality] Collecting data and setting recording conditions using Logger Utility Setting the initial IP address using Logger Utility Setting and controlling recording using communication commands Manually acquiring data using an FTP Server Automatically sending data via FTP (FTP client) HTTP server function XCP on Ethernet (TCP) NTP client function |
| External media | USB Drive, Operation guaranteed: Z4006 (16 GB) SD memory card/SDHC memory card supported, Operation guaranteed: Z4001 (2 GB), Z4003 (8 GB) | |
| External control terminal | Pulse/logic input (1), External sampling input (1), External input and output (4), Alarm output (4), GND terminal (5), CAN interface (1) | Pulse/logic input (1), External sampling input (1), External input and output (4), Alarm output (4), GND terminal (5) |
| Dimensions and weight | - No module: Approx. 80W × 166H × 238D mm (3.1W × 6.5H × 9.4D in.) (excluding protruding parts), Approx. 1.5 kg (3.3 lbs) - With one M7100 installed: Approx. 134W × 166H × 263D mm (5.3W × 6.5H × 10.4D in.) (excluding protruding parts) - With ten M7100 installed: Approx. 620W × 166H × 263D mm (24.4W × 6.5H × 10.4D in.) (excluding protruding parts) | |
| Included accessories | Operating Precautions ×1, Startup Guide ×1, DVD ×1 (Startup Guide, Instruction Manual, Logger Utility, Logger Utility Instruction Manual, CAN Editor, CAN Editor Instruction Manual, Communication Command Instruction Manual) | |
Note
This product does not include an AC adapter. Either the AC Adapter Z1016, Power Cable L1012, or the AC Power Module M1100 must be purchased separately. In case of combining with the M7103, the AC Power Module M1100 is required.
Introducing a revolutionary data logger system, perfect for embedded applications and essential for evaluating energy-efficient products.
Integrating high-precision power and temperature measurements, this system is crucial for comprehensive data on temperature, power consumption, and power conversion efficiency.

Among PV inverters, string inverters are being engineered to operate at higher voltages and to provide more input circuits in order to facilitate energy-efficient operation. Equipment used on lines producing such inverters must support high voltages while providing sufficient expandability to accommodate a growing number of measurement points, all in a smaller testing equipment footprint. Hioki developed the M7103 to satisfy these requirements.

| Module | Power Measurement Module M7103 |
|---|---|
| Max. rated terminal-to-ground voltage | 1000 V DC, 1000 V AC (CAT III) 1500 V DC, 1000 V AC (CAT II) |
| Measurement range | Voltage: 6 V to 1500 V (8 ranges) Current: 40 mA to 2000 A (6 ranges, depends on the current sensor) |
| Number of channels | 3 channels per module |
| Sampling rate | Up to 5 ms |
| External view | ![]() |
| For more product details | In order to use the M7103, the AC Power Module M1100 must be purchased separately. |
Battery packs consist of many battery cells that are connected in series. Since variability in cell characteristics can lead to a decline in the battery pack’s overall performance, it’s critical to ascertain voltage and temperature behavior at the cell level.
Furthermore, it’s necessary to make a comprehensive evaluation of the battery pack’s overall characteristics during charge/discharge testing. This can be done by measuring individual cells’ voltage and temperature at the same time as total voltage and total current.
Manufacturers are designing batteries of increasingly high voltage for use in electric vehicles (EVs).
As battery voltages rise from 400 V to 800 V, it becomes harder to measure battery cells’ voltage and temperature safely. Instruments used to conduct charge/discharge testing of these high-voltage battery packs must now have higher terminal-to-ground and module-to-module voltage then before.

Choose and combine the suitable module for your application.
For measuring the system's total voltage and total current, select the Power Measurement Module M7103.
| Module | Voltage/Temp Module M7100 | Voltage/Temp Module M7102 |
|---|---|---|
| Battery packs | For 600 V to 1500 V battery packs | For 600 V or lower battery packs |
| Max. rated terminal-to-ground voltage | 1500 V DC, 1000 V AC (CAT II) | 600 V DC, 600 V AC (CAT II) |
| Max. rated module-to-module voltage | 1500 V DC, 1000 V AC | 600 V DC, 600 V AC |
| Max. number of channels | 15 channels per module | 30 channels per module |
| Sampling rate | Up to 5 ms | Up to 10 ms |
| External view | ![]() | ![]() |
| For more product details |
| Functionality | LR8102 Advanced model | LR8101 Standard model |
|---|---|---|
| Connect up to 10 measurement modules | ✓ | ✓ |
| Save data on an SD card or USB drive | ✓ | ✓ |
| Control the instrument and transfer data using communication commands | ✓ | ✓ |
| Data output based on UDP (Transfer high-speed data) (*1) | ✓ | N/A |
| Multiple loggers synchronized for measurement (*2) | ✓ | N/A |
| Data output via CAN (*3) | ✓ | N/A |
| External view | ![]() | ![]() |
*1: Data output based on UDP
Measurement data are output for every sampling in real time. The fastest speed is achieved with intervals of 5 ms.
This is useful when realtime processing is required, such as HIL.
*2: Multiple loggers synchronized for measurement
Synchronized measurement is enabled with an optional Optical Connection Cable L6101 (1 m) or Optical Connection Cable L6102 (10 m).
The measurement data from all of the synchronized instruments can be output from LAN2 of the primary instrument.
*3: Data output via CAN
The measured value can be output via a Controller Area Network (CAN).
The value can be used for data integration with the information of an in-vehicle device, such as the battery management system (BMS).
Key Features Acquire CAN FD/CAN data immediately, simply by pinching probes over wire insulation with one-hand Eliminate concerns by using non-contact sensing technology Use in a diverse array of development and evaluation applications that demand reliability
• Probe kompak untuk lingkungan CAT III 1000V • Mode gelombang: Mengamati bentuk gelombang sesaat • Mode RMS: Amati bentuk gelombang nilai RMS • Area penggunaan utama 1. Sirkuit baterai tegangan tinggi pada EV, HEV, dan mobil lain 2. Sirkuit bertegangan tinggi pada peralatan terkait energi seperti sel fotovoltaik 3. Sirkuit saluran listrik komersial (480 Vrms, dll.) 4. Suara lonjakan tegangan tinggi dari inverter, motor, solenoida, dll.
Key Features Thinner cables are easy to use in confined spaces and with complicated wiring (-01, -02) Shaped so that it’s easy to route through complex wiring Easily supports large current measurements up to 5000 A Wide 10 Hz to 20 kHz band with excellent frequency characteristics Choose from three conductor diameter sizes Combine with Hioki power meters or Memory HiCorders (with BNC input terminals)
Key Features Combined accuracy with HIOKI power analyzer PW8001, PW6001 and PW3390 is specified. For details of combined accuracy, refer to the instruction manual. Measures high-current up to 2000 A for EV, HEV and other electric vehicles Improved noise resistance performance through a stronger shield lets you accurately measure current buried in noise High accuracy measurement realized through flat frequency characteristics and CMRR performance More enhanced environmental resistance performance than ever before lets you measure in -40 to 85°C situations Superior frequency characteristics of DC to 1 MHz (amplitude) Meet a wide range of applications from measuring battery charge/discharge to the secondary side of inverters in photovoltaic power generation and fuel cell evaluation, etc. Monitor waveforms when paired with oscilloscopes or Memory HiCorders and Sensor Unit