Key Features Add measurement modules as needed to create the measurement system you need [LR8102] Add channels by synchronizing sampling across multiple loggers [LR8102] Transfer high-speed data in real time

General specifications

Accuracy guaranteed: 1 year

Product modelData Logger LR8102Data Logger LR8101
Modules that can be connectedSee [Options] > [Connectable measurement modules]
Maximum number of module connections10 (maximum of 4 units for M7103)
Maximum number of synchronizable loggers10
(Requires optical connection cables)
N/A
Power supplyAC adapter: AC Adapter Z1016 (operates on 12 V DC ±10%)
External power supply: 10 V DC to 30 V DC
AC Power Module M1100: Always required when using the Power Measurement Module M7103.
Operating temperature and humidity range−10°C to 50°C (14°F to 122°F), 80% RH or less (non-condensing)
Number of LAN ports21
Communication interface[LAN1 functionality]
Collecting data and setting recording conditions using Logger Utility
Setting the initial IP address using Logger Utility
Setting and controlling recording using communication commands
Manually acquiring data using an FTP Server
Automatically sending data via FTP (FTP client)
HTTP server function
XCP on Ethernet (TCP)
NTP client function

[LAN2 functionality]
XCP on Ethernet (UDP)
Measurement data can be output by UDP
[LAN1 functionality]
Collecting data and setting recording conditions using Logger Utility
Setting the initial IP address using Logger Utility
Setting and controlling recording using communication commands
Manually acquiring data using an FTP Server
Automatically sending data via FTP (FTP client)
HTTP server function
XCP on Ethernet (TCP)
NTP client function
External mediaUSB Drive, Operation guaranteed: Z4006 (16 GB)
SD memory card/SDHC memory card supported, Operation guaranteed: Z4001 (2 GB), Z4003 (8 GB)
External control terminalPulse/logic input (1), External sampling input (1), External input and output (4), Alarm output (4), GND terminal (5), CAN interface (1)Pulse/logic input (1), External sampling input (1), External input and output (4), Alarm output (4), GND terminal (5)
Dimensions and weight- No module:
Approx. 80W × 166H × 238D mm (3.1W × 6.5H × 9.4D in.) (excluding protruding parts), Approx. 1.5 kg (3.3 lbs)
- With one M7100 installed:
Approx. 134W × 166H × 263D mm (5.3W × 6.5H × 10.4D in.) (excluding protruding parts) 
- With ten M7100 installed:
Approx. 620W × 166H × 263D mm (24.4W × 6.5H × 10.4D in.) (excluding protruding parts)
Included accessoriesOperating Precautions ×1, Startup Guide ×1, DVD ×1 (Startup Guide, Instruction Manual, Logger Utility, Logger Utility Instruction Manual, CAN Editor, CAN Editor Instruction Manual, Communication Command Instruction Manual)

Note

This product does not include an AC adapter. Either the AC Adapter Z1016, Power Cable L1012, or the AC Power Module M1100 must be purchased separately. In case of combining with the M7103, the AC Power Module M1100 is required.

 

Modular-Based Data Logger System: Versatility and High Accuracy

Offers multi-channel capability, high-voltage rating, all while maintaining the high-accuracy of a power analyzer class instruments

Introducing a revolutionary data logger system, perfect for embedded applications and essential for evaluating energy-efficient products.

Integrating high-precision power and temperature measurements, this system is crucial for comprehensive data on temperature, power consumption, and power conversion efficiency.

Key Performance Features:

  • High Precision: Power analyzer class accuracy for high voltage, high current, and high-power measurements
  • Scalability and Versatility: Supports up to 3000 channels for voltage and temperature, and 120 channels for power measurement
  • High Speed: Data refresh interval 5 ms
  • High-Precision Current Sensors: Measures up to 2000 A

Realizing a Compact, High-precision PV Inverter Testing System
For PV inverter production lines

Introducing a modular power meter that’s ideal for PV inverter production line use

Among PV inverters, string inverters are being engineered to operate at higher voltages and to provide more input circuits in order to facilitate energy-efficient operation. Equipment used on lines producing such inverters must support high voltages while providing sufficient expandability to accommodate a growing number of measurement points, all in a smaller testing equipment footprint. Hioki developed the M7103 to satisfy these requirements.

ModulePower Measurement Module M7103
Max. rated terminal-to-ground voltage1000 V DC, 1000 V AC (CAT III)
1500 V DC, 1000 V AC (CAT II)
Measurement rangeVoltage: 6 V to 1500 V (8 ranges)
Current: 40 mA to 2000 A (6 ranges, depends on the current sensor)
Number of channels3 channels per module
Sampling rateUp to 5 ms
External viewM7103 image
For more product details

In order to use the M7103, the AC Power Module M1100 must be purchased separately.

Brochure/CatalogView example setups, learn more about product advantages, and explore the model selection guide.PDF

Unmatched Capability for Capturing Data from High-Voltage Battery Packs
Suitable for Battery Charge/Discharge Testing

Product Concept

Battery packs consist of many battery cells that are connected in series. Since variability in cell characteristics can lead to a decline in the battery pack’s overall performance, it’s critical to ascertain voltage and temperature behavior at the cell level.
Furthermore, it’s necessary to make a comprehensive evaluation of the battery pack’s overall characteristics during charge/discharge testing. This can be done by measuring individual cells’ voltage and temperature at the same time as total voltage and total current.

Manufacturers are designing batteries of increasingly high voltage for use in electric vehicles (EVs). 
As battery voltages rise from 400 V to 800 V, it becomes harder to measure battery cells’ voltage and temperature safely. Instruments used to conduct charge/discharge testing of these high-voltage battery packs must now have higher terminal-to-ground and module-to-module voltage then before.

Modules that are ideal for use in measuring the voltage of stack cells in battery packs and in charge/discharge testing on cell production lines

Choose and combine the suitable module for your application.
For measuring the system's total voltage and total current, select the Power Measurement Module M7103.

ModuleVoltage/Temp Module M7100Voltage/Temp Module M7102
Battery packsFor 600 V to 1500 V battery packsFor 600 V or lower battery packs
Max. rated terminal-to-ground voltage1500 V DC, 1000 V AC (CAT II)600 V DC, 600 V AC (CAT II)
Max. rated module-to-module voltage1500 V DC, 1000 V AC600 V DC, 600 V AC
Max. number of channels15 channels per module30 channels per module
Sampling rateUp to 5 msUp to 10 ms
External viewM7100 imageM7102 image
For more product details

Solutions for charge/discharge testing of batteries

Brochure/CatalogView example setups, learn more about product advantages, and explore the model selection guide.PDF

Application Note: Charge/Discharge Testing of High-Voltage BatteriesRead how to test and evaluate the voltage and temperature for each battery cell. This article also introduces configuration for a standard 400 V battery pack and advanced evaluation system (800 V battery pack).

Application Note: A data logger that can interoperate with an HIL simulation system thanks to high-speed, real-time data outputThis article introduces an example of how to measure voltage and temperature of individual battery cells and send the acquired data to a Hardware-in-the-loop (HIL) simulation system.

Differences between the LR8101 (Standard model) and LR8102 (Advanced model)

FunctionalityLR8102
Advanced model
LR8101
Standard model
Connect up to 10 measurement modules
Save data on an SD card or USB drive
Control the instrument and transfer data using communication commands
Data output based on UDP (Transfer high-speed data)
(*1)
N/A
Multiple loggers synchronized for measurement
(*2)
N/A
Data output via CAN
(*3)
N/A
External viewLR8102 imageLR8101 image

*1: Data output based on UDP

Measurement data are output for every sampling in real time. The fastest speed is achieved with intervals of 5 ms.
This is useful when realtime processing is required, such as HIL.

*2: Multiple loggers synchronized for measurement

Synchronized measurement is enabled with an optional Optical Connection Cable L6101 (1 m) or Optical Connection Cable L6102 (10 m).
The measurement data from all of the synchronized instruments can be output from LAN2 of the primary instrument.

*3: Data output via CAN

The measured value can be output via a Controller Area Network (CAN).
The value can be used for data integration with the information of an in-vehicle device, such as the battery management system (BMS).

 

Produk Terkait

NON-CONTACT CAN SENSOR SP7001, SP7002

NON-CONTACT CAN SENSOR SP7001, SP7002

Key Features Acquire CAN FD/CAN data immediately, simply by pinching probes over wire insulation with one-hand Eliminate concerns by using non-contact sensing technology Use in a diverse array of development and evaluation applications that demand reliability

Probes Sensors Hioki
Detail Produk
DIFFERENTIAL PROBE P9000

DIFFERENTIAL PROBE P9000

• Probe kompak untuk lingkungan CAT III 1000V • Mode gelombang: Mengamati bentuk gelombang sesaat • Mode RMS: Amati bentuk gelombang nilai RMS • Area penggunaan utama 1. Sirkuit baterai tegangan tinggi pada EV, HEV, dan mobil lain 2. Sirkuit bertegangan tinggi pada peralatan terkait energi seperti sel fotovoltaik 3. Sirkuit saluran listrik komersial (480 Vrms, dll.) 4. Suara lonjakan tegangan tinggi dari inverter, motor, solenoida, dll.

Probes Sensors Hioki
Detail Produk
AC FLEXIBLE CURRENT SENSOR CT9667

AC FLEXIBLE CURRENT SENSOR CT9667

Key Features Thinner cables are easy to use in confined spaces and with complicated wiring (-01, -02) Shaped so that it’s easy to route through complex wiring Easily supports large current measurements up to 5000 A Wide 10 Hz to 20 kHz band with excellent frequency characteristics Choose from three conductor diameter sizes Combine with Hioki power meters or Memory HiCorders (with BNC input terminals)

Probes Sensors Hioki
Detail Produk
AC/DC CURRENT SENSOR CT6877

AC/DC CURRENT SENSOR CT6877

Key Features Combined accuracy with HIOKI power analyzer PW8001, PW6001 and PW3390 is specified. For details of combined accuracy, refer to the instruction manual. Measures high-current up to 2000 A for EV, HEV and other electric vehicles Improved noise resistance performance through a stronger shield lets you accurately measure current buried in noise High accuracy measurement realized through flat frequency characteristics and CMRR performance More enhanced environmental resistance performance than ever before lets you measure in -40 to 85°C situations Superior frequency characteristics of DC to 1 MHz (amplitude) Meet a wide range of applications from measuring battery charge/discharge to the secondary side of inverters in photovoltaic power generation and fuel cell evaluation, etc. Monitor waveforms when paired with oscilloscopes or Memory HiCorders and Sensor Unit

Probes Sensors Hioki
Detail Produk